Krypson Infra Corporate Logo
Turnkey Industrial / Steel Structures / PEB & PUF Technical Deep-Dive
Technical Specification Dossier • DOC ID: KYP-PEB-2026-X4

Pre-Engineered Building Systems & Advanced Thermal Cladding

Full architectural analysis, metallurgical yield tolerances, structural fabrication parameters, and PIR/PUF thermal envelope integration engineered by Krypson Infra Private Limited per IS 800:2007 & MBMA standards.

Steel Grade E350 / A572 350 MPa Yield
Thermal Value λ = 0.022 W/mK Core Coeff
Wind Velocity 50 m/s IS 875 Part 3
Module 01 // Structural Breakdown

PEB Engineering Anatomy & Material Matrix

Explore the 5 core layers of Krypson Infra high-tensile structural frames, secondary cold-rolled load carriers, and polyurethane core envelopes.

architecture PEB Portal Frame Elevation • Schematic CAD View
CAD TOLERANCE ±1.5mm
Primary Rafter (Built-up I)
Tapered Column Base
Continuous Ridge Ventilator
PUF Cladding Envelope
Clear Span Capability Up to 90m Column-free interior
Eave Height 4.5m – 18m Mezzanine ready
Crane Integration 5T to 50T EOT Corbel brackets
01

Primary Built-Up Portal Frames

High-Tensile ASTM A572 / IS 2062 Gr. E350
domain

Custom-fabricated tapered columns and rafter flanges joined via automatic submerged arc welding (SAW). Yield strength 350 MPa with high seismic fatigue resistance.

Fy = 350 MPa AWS D1.1 SAW Welded Hot-Rolled Flanges
02

Secondary Framing (Z & C Purlins)

Cold-Formed Galvanized Steel (275 GSM)
view_week

Precision cold-formed Z & C purlins, eave struts, sag rods, and angle bracings with factory pre-punched staggered holes for quick on-site bolting without hot work.

IS 801 / IS 811 275 GSM Zinc Coating Eave Struts & Ties
03

Continuous Injected PUF / PIR Panels

Rigid Polyurethane Core (40±2 kg/m³)
thermostat

40mm to 150mm thick rigid panels with continuous tongue-and-groove jointing and concealed fasteners, eliminating cold-bridging for clean rooms and warehouses.

λ = 0.022 W/mK Fire Class B1 / B2 Zero CFC / ODP
04

High-Yield Galvalume Sheeting

AZ150 Alloy • 550 MPa Yield Strength
layers

Alu-Zinc 150 GSM coated high-tensile 550 MPa profiled steel sheeting with anti-siphoning capillary grooves preventing leakages under torrential rain.

05

Daylighting & Natural Aerodynamics

Polycarbonate Sheets & Turbo Ventilators
air

Aero-dynamic continuous throat ridge vents and stainless-steel bearing rotary wind ventilators combined with UV-stabilized 2mm polycarbonate sheets for energy-neutral lighting.

Manufacturing & Continuous Panel Profiling

Heavy fabrication facilities equipped with computerized multi-torch CNC cutting tables and automatic high-pressure polyurethane foaming lines.

Primary Section SAW Welding

CNC Automated Flange Alignment

Flange and web assemblies cut using multi-head CNC plasma cutters, followed by mechanized submerged arc welding for deep uniform penetration.

IS 2062: E350 Quality Verified
Continuous Line PUF Press

High-Density Injected Foam Core

Automated continuous polyurethane metering at high pressure prevents thermal voids and achieves uniform 40 kg/m³ insulation density across full length.

Thermal: U-Value 0.28 W/m²K (80mm)
Precision Site Erection

100% Bolted On-Site Assembly

Zero hot-works or cutting required on erection field. All primary moments joined using Grade 8.8 / 10.9 high-strength friction grip (HSFG) bolts.

HSFG Torque Calibrated Fastening
Module 02 // Engineering Standards & Codes

Civil & Structural Design Compliance Sheet

Rigorous engineering benchmarks configured in compliance with national and international building codes.

verified STAAD.Pro & Tekla Structures Verified
Structural Domain Mandatory Code Reference Krypson Engineering Parameters Safety Margin & QA
engineering Steel Structure Design IS 800:2007 (LSD) / MBMA-2010 Limit State Method, High Tensile E350 Grade steel, Class 1/2 plastic sections Safety Factor γm = 1.10
air Wind Dynamic Loadings IS 875 (Parts 1-3) : 2015 Engineered for basic wind speeds up to 50 m/s (180 km/h); terrain cat 1-4 with internal pressure coeff ±0.7 Aero-Drag Ratio 1.25
vibration Seismic Resistance IS 1893 (Part 1) : 2016 Seismic Zone IV & V compliant, ductile moment-resisting steel frames, response reduction factor R=4 to 5 Zone IV & V Certified
precision_manufacturing Structural Welding Standard AWS D1.1 / IS 9595 Submerged Arc Welding (SAW) & Gas Metal Arc Welding (GMAW) by certified Level 2 welders 100% Visual + MPT
straighten Deflection Tolerances MBMA / AISC 360-16 Rafter vertical limit: L/180 (gravity), Column horizontal sway: H/150 to H/300 for crane runways Optimum Rigidity
thermostat PUF/PIR Panel Insulation IS 12436 / ASTM C591 Cyclopentane-blown rigid PUF/PIR core, density 40 kg/m³, thermal conductivity λ=0.022 W/mK Class B1 Fire Rated
* Anchor bolt foundation arrangements (M24 to M48 Grade 8.8) configured custom per certified geotechnical reports. Request Structural Calculation Dossier arrow_forward

Turnkey Execution & Quality Assurance Sequence

Zero-compromise non-destructive testing (NDT) and calibration standards applied from mill receipt to final roof ridge sealing.

01 biotech

Raw Material UT & Mill Verification

Every steel plate coil receives Ultrasonic Testing (UT per ASTM A435) for internal lamination defects. Heat number chemistry matched against mill test certificates.

QA Deliverable MTC / ASTM Mill Test Dossier
02 flare

Weld NDT & Dye Penetrant (DPT)

Submerged Arc Welds and critical moment flange-to-web joins tested via Magnetic Particle Testing (MPT) and Liquid Dye Penetrant (DPT) per AWS D1.1 structural welding specifications.

QA Deliverable AWS D1.1 Certified Welder Log
03 square_foot

Shop Pre-Fit & Laser Geometry

Sample portal spans pre-assembled on the factory floor using laser distance meters. Hole center-to-center distances, rafter sweep, and flange squaring held within ±1.5mm.

QA Deliverable Dimensional Clearance Certificate
04 task_alt

Site Torque & Envelope Sealing

HSFG calibrated torque-wrench testing for bolted moments, continuous lap-screw inspection, thermal envelope scanning for PUF seals, and weatherproofing sign-off.

QA Deliverable Commissioning & Handover Dossier
Documentation

Technical Specs & Engineering Downloads

Obtain standard connection drawings, beam-to-column moment CAD dwg blocks, and PUF panel thermal calculation charts for your project planning.

picture_as_pdf

Krypson PEB Technical Catalog

PDF • 44 Pages • 14.8 MB
Download
thermostat

PUF & PIR Cladding Data Sheet

PDF • U-Value & Fire Rating • 4.2 MB
Download
architecture

Standard CAD Joint Profiles (DWG)

ZIP Archive • AutoCAD Blocks • 18.2 MB
Download
factory

Our Punjab facility fabricates in excess of 1,500 Metric Tons of structural steel and produces 45,000 m² of continuous PUF panels each month, serving projects pan-India.

Fast Structural Estimation

Technical RFQ Consultation

schedule 24h Turnaround
verified Category: Pre-Engineered Buildings & PUF Panels
KYP-PEB-2026
Estimated Building Envelope Dimensions
m
m
m
support_agent
Structural Advisory Desk

Speak Directly with a Krypson PEB Design Specialist

call
Phone Hotline +91 8894703952
alternate_email
Design Desk info@kkrypsoninfra.com
Built and Designed by Namedays